1.
Rev. neurol. (Ed. impr.) ; 78(1)1 - 15 de Enero 2024. tab, graf
Artigo em Inglês, Espanhol | IBECS | ID: ibc-229063

RESUMO

Introducción La enfermedad de Huntington (EH) es un trastorno raro neurodegenerativo. La información fiable del estado nutricional, especialmente de la composición corporal, es crítica en clínica y en investigación. La facilidad de aplicación y portabilidad del análisis de la bioimpedancia de múltiples frecuencias (mfBIA) la convierten en una herramienta atractiva para medirla, pero se desconoce su precisión en la EH. Objetivo Evaluar la precisión del mfBIA frente a la absorciometría dual de rayos X (DEXA) en la EH. Pacientes y métodos Estudio transversal, observacional y unicéntrico. La EH se midió con la subescala motora de la escala unificada de valoración de la EH y con la capacidad funcional total. La composición corporal se valoró según la masa libre de grasa (MLG), la masa grasa (MG), el índice de masa libre de grasa (IMLG) y el índice de masa grasa (IMG). Se utilizó el coeficiente de correlación intraclase con intervalos de confianza al 95% y estimaciones de sesgo mediante gráficos de Bland-Altman. Resultados Se incluyó a 16 pacientes, siete hombres y nueve mujeres, con edad media de 58,5 (32-68) años, capacidad funcional total de 10 (3-13) y escala unificada de valoración de la EH de 31 (7-85). La fiabilidad era alta entre el mfBIA y la DEXA para el IMLG en hombres, 0,88 (intervalo de confianza al 95%: 0,17-0,98), y mujeres, 0,9 (intervalo de confianza al 95%: 0,61-0,98); y para el IMG en hombres, 0,97 (intervalo de confianza al 95%: 0,83-0,99), y mujeres, 0,91 (intervalo de confianza al 95%: 0,68-0,98). El mfBIA sobreestimó ligeramente la MLG, la MG, el IMG y el IMLG en los hombres, pero subestimó el IMLG en las mujeres. Conclusiones El mfBIA es un método fácil de usar, seguro, no invasivo y preciso para medir la composición corporal y el estado nutricional en pacientes con EH leve-moderada. (AU)


INTRODUCTION Huntington´s disease (HD) is a rare neurodegenerative disorder. Reliable information about nutritional status, especially body composition from individuals with HD is critical for clinical care and research. The ease of application and portability of multiple frequencies bioelectrical impedance analysis (mfBIA) make it an attractive tool for measuring body composition, but its accuracy in HD is unknown. AIM To evaluate the accuracy of mfBIA vs. Dual X-ray absorptiometry (DEXA) in HD. PATIENTS AND METHODS Cross-sectional, observational, and single-center study. HD severity was measured using motor subscale of the unified Huntington´s disease rating scale (m-UHDRS) and the total functional capacity (TFC). Body composition was measured in terms of fat-free mass (FFM), fat mass (FM), fat-free mass index (FFMI), and fat mass index (FMI). Using Bland-Altman plots, we analyzed reliability between DEXA and mfBIA using the Intraclass Correlation Coefficient with 95% confidence intervals (CI) and bias estimates for all. RESULTS We included 16 patients with HD, 7 men, and 9 women, median age of 58.5 (32;68) years, TFC: 10 (3;13), and m-UHDRS: 31 (7;85). The reliability between mfBIA and DEXA were high for FFMI in men: 0.88 (95% CI 0.17-0.98), and women: 0.90 (95% CI 0.61- 0.98); for FMI, men: 0.97 (95% CI 0.83-0.99), and women: 0.91 (95% CI 0.68-0.98). Compared to DEXA, mfBIA slightly overestimated FFM, FM, FMI and FFMI in men and underestimated FFMI in women. CONCLUSIONS mfBIA is an easy-to-use, safe, non-invasive, accurate method for measuring body composition and nutritional status in patients with mild-moderate HD. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Doença de Huntington , Absorciometria de Fóton/instrumentação , Composição Corporal , Estudos Transversais , Impedância Elétrica , Índice de Massa Corporal
2.
Osteoporos Int ; 33(9): 1981-1988, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35614236

RESUMO

Scanner mismatch occurs frequently with follow-up dual-energy x-ray absorptiometry (DXA) scans. Nearly one-in-five follow-up DXA scans were conducted on non-cross-calibrated scanners (scanner mismatch) and more than a quarter of patients who had a follow-up DXA scan had experienced scanner mismatch. INTRODUCTION: Detecting significant changes in bone mineral density (BMD) with dual-energy x-ray absorptiometry (DXA) scanners relies on the least significant change (LSC). Results from two different DXA scanners can only be compared, albeit with decreased sensitivity for change, if the LSC between the two scanners has been directly determined through cross-calibration. Performing follow-up DXA scans on non-cross-calibrated scanners (scanner mismatch) has safety and economic implications. This study aims to determine the proportion of scanner mismatch occurring at a population level. METHODS: All patients who completed at least two DXA scans between 1 April 2009 and 31 December 2018 in the province of Alberta, Canada, were identified using population-based health services databases. Scanner mismatch was defined as a follow-up DXA scan completed on a DXA scanner that differed from and was not cross-calibrated to the previous DXA scanner. Multivariate logistic regression models were used to assess predictive factors that may contribute to scanner mismatch. RESULTS: A total of 264,866 patients with 470,641 follow-up DXA scans were identified. Scanner mismatch occurred in 18.9% of follow-up DXA scans; 28.7% of patients experienced at least one scanner mismatch. Longer duration between scans (OR 1.25, 95% CI 1.24-1.26) and major osteoporotic fracture history before index scan (OR 1.06, 95% CI 1.03-1.08) increased risk of scanner mismatch. Osteoporosis medication use before index scan (OR 0.89; 95% CI 0.88-0.91), recency of follow-up scans (OR 0.98, 95% CI 0.73-0.98), female sex (OR 0.97, 95% CI 0.94-1.00), and age at last scan (OR 0.99, 95% CI 0.99-1.00) were associated with lower risk of scanner mismatch. CONCLUSION: Scanner mismatch is a common problem, occurring in one-in-five follow-up DXA scans and affecting more than a quarter of patients. Interventions to reduce this large proportion of scanner mismatch are necessary.


Assuntos
Absorciometria de Fóton , Densidade Óssea , Absorciometria de Fóton/instrumentação , Absorciometria de Fóton/métodos , Absorciometria de Fóton/normas , Alberta , Feminino , Seguimentos , Humanos , Masculino , Osteoporose/diagnóstico por imagem , Fatores Sexuais , Fatores de Tempo
3.
J Clin Densitom ; 24(2): 330-337, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33199190

RESUMO

Bone Strain Index (BSI) is a new finite element analysis tool applied to hip dual energy X-ray absorptiometry scans. The aim of this study was to assess the short-term precision error of BSI on the proximal femur, both on a phantom and patients. The International Society for Clinical Densitometry guidelines were followed for short-term precision error assessment. Dual energy X-ray absorptiometry measurements were performed on an anthropomorphic femur phantom that was scanned twice for 30 times, for a total of 60 scans. For the in vivo part, 30 subjects were scanned twice. BSI precision error was compared to that of bone mineral density (BMD). Both for the phantom and the in vivo study BSI reproducibility was lower compared to that of BMD, as the precision error of BSI resulted 3 times higher compared to that BMD. For phantom measurements, the highest precision value was that of total femur (TF) BMD (coefficient of variation [CoV] = 0.63%, reproducibility = 98.24%), while the lowest precision was the femoral neck (FN) BSI (CoV = 3.08%, reproducibility = 91.48%). Similarly, for the in vivo study, the highest precision was found at TF BMD (CoV = 1.36%, reproducibility = 96.22%), while the lowest value of precision was found for FN BSI (CoV = 4.17%, reproducibility = 88.46%). Reproducibility at TF was always better compared to that of the FN. BSI precision error was about 3 times higher compared to BMD, confirming previous results of lumbar spine BSI. The main source of variability of this new software is related to patient positioning.


Assuntos
Absorciometria de Fóton , Fêmur/diagnóstico por imagem , Análise de Elementos Finitos , Osteoporose/diagnóstico , Software , Absorciometria de Fóton/instrumentação , Absorciometria de Fóton/métodos , Idoso , Densidade Óssea , Feminino , Humanos , Masculino , Osteoporose/metabolismo , Osteoporose/fisiopatologia , Posicionamento do Paciente/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
4.
PLoS One ; 15(5): e0233053, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32401808

RESUMO

BACKGROUND: The new generation of dual energy X-ray absorptiometry (DXA) scanners provide visceral adipose tissue (VAT) estimates by applying different algorithms to the conventional DXA-derived fat parameters such as total fat, trunk fat and android fat for the same image data. OBJECTIVE: This cross-sectional study aimed to investigate whether VAT estimates from Hologic scanners are better predictors of VAT than conventional DXA parameters in pre-pubertal children, and to explore the discrimination ability of these VAT methods for cardiometabolic risks. METHODS: Healthy pre-pubertal children aged 7-10 years were recruited for basic anthropometric, DXA and magnetic resonance imaging (MRI) measurements. Laboratory tests included lipid profile, glycaemic tests and blood pressure. RESULTS: All VAT methods had acceptable to excellent performance for the diagnosis of dyslipidaemia (area under the curve [AUC] = 0.753-0.837) and hypertensive risk (AUC = 0.710-0.821) in boys, but suboptimal performance for these risks in girls, except for VAT by MRI in the diagnosis of dyslipidaemia. In both sexes, all VAT methods had no or poor discrimination ability for diabetes risk. CONCLUSIONS: DXA-derived VAT estimates are very highly correlated with standard methods but has equivalent discrimination abilities compared to the existing DXA-derived fat estimates.


Assuntos
Absorciometria de Fóton/instrumentação , Diabetes Mellitus/diagnóstico , Dislipidemias/diagnóstico por imagem , Hipertensão/diagnóstico , Gordura Intra-Abdominal/diagnóstico por imagem , Lipídeos/análise , Algoritmos , Determinação da Pressão Arterial , Criança , Estudos Transversais , Diabetes Mellitus/metabolismo , Dislipidemias/metabolismo , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Puberdade , Medição de Risco
5.
Mil Med ; 185(Suppl 1): 430-434, 2020 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-32074354

RESUMO

INTRODUCTION: Musculoskeletal overuse injuries are a serious problem in the military, particularly in basic combat training, resulting in hundreds of millions of dollars lost because of limited duty days, medical treatment, and high rates of reinjury. Injury risk models have been developed using peripheral computed tomography (pQCT)-based injury correlates. However, pQCT image capture on large number of recruits is not practical for military settings. Thus, this article presents a method to derive spatial density pQCT images from much lower resolution but more accessible dual-energy X-ray absorptiometry (DXA). MATERIALS AND METHODS: Whole-body DXA images and lower leg pQCT images for 51 male military recruits were collected before a 40-day School of Infantry. An artificial neural network model was constructed to relate the DXA density profiles to spatial pQCT density at the 38% and 66% tibial locations. RESULTS: Strong correlation, R2 = 0.993 and R2 = 0.990 for the 38% and 66% pQCT slices, respectively, was shown between spatial density predicted by the artificial neural network model and raw data. CONCLUSIONS: High potential exists to create a practical protocol using DXA in place of pQCT to assess stress fracture risk and aid in mitigating musculoskeletal injuries seen in military recruits.


Assuntos
Absorciometria de Fóton/métodos , Transtornos Traumáticos Cumulativos/diagnóstico por imagem , Militares/estatística & dados numéricos , Tíbia/lesões , Absorciometria de Fóton/instrumentação , Absorciometria de Fóton/normas , Densidade Óssea/fisiologia , Transtornos Traumáticos Cumulativos/diagnóstico , Humanos , Masculino , Militares/educação , Tíbia/diagnóstico por imagem , Adulto Jovem
6.
Rev. int. med. cienc. act. fis. deporte ; 19(76): 617-626, dic. 2019. tab
Artigo em Espanhol | IBECS | ID: ibc-187235

RESUMO

El objetivo de este estudio fue evaluar la densidad mineral ósea (DMO) y el contenido mineral óseo (CMO) de los segmentos corporales durante un periodo de entrenamiento de seis meses. Se evaluaron a 41 futbolistas juveniles profesionales en dos momentos, una al comienzo (TI) y otra al final (TF) de la intervención con el equipo de absorciometría dual de rayos X (DEXA). Se lograron aumentos significativos en la DMO en los segmentos corporales de la cadera, columna lumbar, triangulo de Ward, tronco y del cuerpo total (p<0.05). También se obtuvo un incremento significativo del CMO en la cadera, columna lumbar, pierna, tronco y costillas (p<0.05). El entrenamiento de futbol fortaleció el CMO y la DMO del hueso de la extremidad inferior y de la caja torácica, con lo cual el fútbol podría ser una actividad útil para la mejorar la mineralización y fortalecimiento del hueso, para prevenir lesiones y fracturas


The objective of this study was to assess bone mineral density (BMD) and bone mineral content (BMC) of body segments for a six months training period. 41 professional youth players were evaluated in two moments, one at the beginning (TI) and another at the end (TF) of the intervention with the dual energy x-ray absorptiometry equipment (DEXA). Significant increases in BMD were achieved in the body segments of the hip, lumbar spine, ward triangle, trunk and total body (p <0.05). There was also a significant increase in BMC in the hip, lumbar spine, leg, trunk and ribs (p <0.05). Soccer training strengthened the BMC and BMD of the lower limb bone and the rib cage, which could be a useful activity to improve bone mineralization and strengthening, to prevent injuries and fractures


Assuntos
Humanos , Masculino , Adolescente , Futebol/fisiologia , Densidade Óssea/fisiologia , Antropometria , Calcificação Fisiológica/fisiologia , Traumatismos em Atletas/prevenção & controle , Remodelação Óssea/fisiologia , Estudos Longitudinais , Absorciometria de Fóton/instrumentação
7.
J Clin Densitom ; 22(4): 472-483, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31558404

RESUMO

In preparation for the International Society for Clinical Densitometry Position Development Conference (PDC) 2019 in Kuala Lumpur, Malaysia, a cross-calibration and precision task force was assembled and tasked to review the literature, summarize the findings, and generate positions to answer 4 related questions provided by the PDC Steering Committee, which expand upon the current ISCD official positions on these subjects. (1) How should a provider with multiple dual-energy X-ray absorptiometry (DXA) scanners of the same make and model calculate least significant change (LSC)? (2) How should a provider with multiple DXA systems with the same manufacturer but different models calculate LSC? (3) How should a provider with multiple DXA systems from different manufacturers and models calculate LSC? (4) Are there specific phantom procedures that one can use to provide trustworthy in vitro cross calibration for same models, different models, and different makes? Based on task force deliberations and the resulting systematic literature reviews, 3 new positions were developed to address these more complex scenarios not addressed by current official positions on single scanner cross calibration and LSC. These new positions provide appropriate guidance to large multiple DXA scanner providers wishing to offer patients flexibility and convenience, and clearly define good clinical practice requirements to that end.


Assuntos
Absorciometria de Fóton/normas , Densidade Óssea , Conferências de Consenso como Assunto , Osteoporose/diagnóstico , Garantia da Qualidade dos Cuidados de Saúde , Absorciometria de Fóton/instrumentação , Calibragem , Desenho de Equipamento , Humanos , Sociedades Médicas
8.
Vet Clin North Am Exot Anim Pract ; 22(3): 397-417, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31395322

RESUMO

Diagnostic imaging relies on interpretation of interactions between the body tissue and various energies, such as x-rays, ultrasound, and magnetic or nuclear energies, to differentiate normal from abnormal tissues. Major technological improvements regarding emission and detection of the energetic waves, as well as reconstruction and interpretation of the images, have occurred. These advances made possible visualization of smaller structures, quantitative evaluation of functional processes, and development of unique imaging-guided procedures. This article reviews the technological advances that allowed development of cone beam computed tomography, dual-energy x-ray absorptiometry, and contrast-enhanced ultrasonography, which all could have applications in exotic pet medicine.


Assuntos
Animais Exóticos , Diagnóstico por Imagem/veterinária , Medicina Veterinária/tendências , Absorciometria de Fóton/instrumentação , Absorciometria de Fóton/métodos , Absorciometria de Fóton/tendências , Absorciometria de Fóton/veterinária , Animais , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada de Feixe Cônico/tendências , Tomografia Computadorizada de Feixe Cônico/veterinária , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Diagnóstico por Imagem/tendências , Humanos , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Ultrassonografia/tendências , Ultrassonografia/veterinária , Medicina Veterinária/instrumentação , Medicina Veterinária/métodos
9.
Nutr. hosp ; 36(4): 919-925, jul.-ago. 2019. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-184719

RESUMO

Introducción: el índice de masa corporal (IMC) es una medida subrogada de la adiposidad corporal, por lo que puede infradiagnosticar sobrepeso y obesidad, lo que hace necesario definir variables más adecuadas para su correcto diagnóstico. Objetivo: comparar la categorización de sobrepeso y obesidad según el porcentaje de grasa medido con absorciometría de rayos X de energía dual (DEXA) con el IMC y la fórmula Clínica Universidad de Navarra - Body Adiposity Estimator (CUN-BAE), así como su relación con la adherencia a la dieta mediterránea, la actividad física y la satisfacción con la imagen corporal. Sujetos y métodos: estudio descriptivo transversal llevado a cabo en una muestra de 64 estudiantes de Medicina. Se determinaron peso, talla, perímetro de cintura, porcentaje de grasa medido con DEXA, adherencia a la dieta mediterránea, nivel de actividad física y satisfacción con la imagen corporal. Resultados: el IMC infradiagnostica sobrepeso respecto al porcentaje de grasa medido por DEXA mientras que la ecuación CUN-BAE presenta una buena correlación. El porcentaje de grasa se asocia inversamente con la satisfacción con la imagen corporal con mayor fuerza que el IMC. Conclusión: se necesitan nuevas herramientas capaces de distinguir los casos con IMC normal cuyo porcentaje de grasa corporal está elevado. Sería útil estudiar si el empleo de un cuestionario de satisfacción con la imagen corporal en personas clasificadas como normopeso podría distinguir a aquellas con una mayor probabilidad de exceso de grasa y así emplear estudios más exhaustivos en este colectivo


Introduction: body mass index (BMI) can under-diagnose overweight and obesity as it is a surrogate measure of central adiposity, making it necessary to define more adequate variables for its correct diagnosis. Objective: to compare the categorization of overweight and obesity according to the percentage of fat measured with dual-energy X-ray absorptiometry (DEXA) with the BMI and the Clínica Universidad de Navarra - Body Adiposity Estimator (CUN-BAE) formula, as well as their relationship with adherence to the Mediterranean diet, physical activity and satisfaction with body image. Subjects and methods: cross-sectional study conducted in 64 medical students. We determined weight, height, waist circumference, percentage of fat measured with DEXA, adherence to the Mediterranean diet, level of physical activity and degree of satisfaction with body image. Results: BMI underdiagnoses overweight with respect to the percentage of fat measured by DEXA while CUN-BAE has a good correlation. Percentage of fat is inversely associated with satisfaction with body image more strongly than the BMI. Conclusion: the limitations of BMI to diagnose excess body fat pose the need for new tools to distinguish patients with normal BMI whose percentage of body fat is high. It would be useful to assess whether the use of a questionnaire of satisfaction with body image in people classified as normal weight could distinguish individuals with a higher probability of excess of fat, and thus, employ more accurate study methods in this group


Assuntos
Humanos , Masculino , Feminino , Adulto , Composição Corporal/fisiologia , Estilo de Vida , Imagem Corporal , Estudantes de Medicina/estatística & dados numéricos , Absorciometria de Fóton/métodos , Absorciometria de Fóton/instrumentação , Dieta Mediterrânea , Índice de Massa Corporal , Estudos Transversais , Sobrepeso , Obesidade , Inquéritos e Questionários , Antropometria , Atividade Motora
10.
J Clin Densitom ; 22(3): 382-390, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30292570

RESUMO

One of the best methods for diagnosing bone disease in humans is site-specific and total bone mineral density (BMD) measurements by Dual-energy X-ray Absorptiometry (DXA) machines. The basic disadvantage of this technology is inconsistent BMD measurements among different DXA machines from different manufacturers due to different image analysis algorithms. The objective of the present study was to apply artificial neural networks (ANNs) to estimate total BMD for diagnosing a population of Egyptians with and without pathology, using extracted features from DXA-DICOM images based on the Histogram and Binary algorithms as compared to reference BMD measurements by DXA machine. The sample size comprised 3000 male and female participants with an age range 22-49 years, who were referred to us for diagnosis and/or treatment and for DXA total body scans in the period from January 2016 till December 2017. We constructed an entry computer data-logging visible unit, where we applied morphological operations to get a specific bone image, and used their extracted feature vectors as inputs to ANNs with cascade training, gathering, and testing for DXA-DICOM image processing. The multilayer feed-forward ANN set up its initial weights, carried out training and initiated the recall mode, and finally observed its decision and interaction based on estimated BMD. The ANN construction was carried out using a 3-layer architecture, with one hidden layer of 85 neurons. The input layer has neuron numbers equal to 256 for the Histogram and 77,365 for Binary algorithms, respectively. Total BMD estimation performance based on the Binary algorithm was capable of identifying all DXA-DICOM images with an accuracy of 100% for the training, cross-validation, and testing of the ANN phases. We believe this strategy will represent the means for standardizing bone measurements of all DXA machines, regardless of the manufacturer.


Assuntos
Absorciometria de Fóton/métodos , Densidade Óssea , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Osteoporose/diagnóstico por imagem , Absorciometria de Fóton/instrumentação , Adulto , Algoritmos , Estudos de Casos e Controles , Egito , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
11.
J Clin Densitom ; 22(3): 429-436, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29681438

RESUMO

Whole-body composition analysis by dual-energy X-ray absorptiometry (DXA) requires subjects to fit within the width limits of the DXA bed. To overcome this limitation, the aim of this study was to validate a partial scanning technique at which the upper left limb is deliberately left unscanned and measurements are "reflected" from the right-side upper limb. A Hologic Explorer-W densitometer was used in a sample of 189 participants, including athletes and nonathletes, ranging from underweight to obese (body mass index: 17.0-40.1 kg/m2). A whole-body scan was analyzed as the reference procedure to determine bone mineral content (BMC), lean soft tissue (LST), and fat mass (FM), and reanalyzed using a partial reflection scanning (RS) technique. RS estimates of BMC were associated with athletic status and differed significantly from reference estimates (p < 0.05). Also, the RS estimates of LST and FM were different (p < 0.05) from those of the reference whole-body scan, although differences were small (0.17 kg, -0.02 kg, and -0.10% for BMC, LST, and FM, respectively). The alternative procedure explained more than 99% of the reference scan variance with low limits of agreement (BMC: -13.8 to 23.9 g [athletes] and -6.3 to 18.0 g [nonathletes]; LST: -0.11 to 0.45 kg; FM: -0.22 to 0.17 kg). Regardless of body mass index, athletic status, and gender, RS is a useful and simple solution to be used in individuals wider than the DXA scan area. However, individual errors for BMC may be higher in athletes engaged in lateral dominant sports practice.


Assuntos
Absorciometria de Fóton/métodos , Atletas , Composição Corporal , Tamanho Corporal , Obesidade , Imagem Corporal Total/métodos , Absorciometria de Fóton/instrumentação , Tecido Adiposo/diagnóstico por imagem , Adolescente , Adulto , Índice de Massa Corporal , Densidade Óssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
12.
Transfusion ; 58(9): 2157-2165, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30179256

RESUMO

BACKGROUND: Donors' hemoglobin (Hb) level must be tested before blood donation. Low Hb is the leading reason for donor deferral. Many donor-related and external factors associated with low Hb are known, but no studies have been conducted concerning the effects of analytical variation on donor Hb measurements and deferrals. STUDY DESIGN AND METHODS: The effects of donors' age, the seasonal and daily distribution of donations, and batch-to-batch variation in HemoCue Hb 201+ cuvettes on donors' capillary Hb (cHb) measurements and deferrals were analyzed for more than 1.7 million donor visits in 2010 to 2016 at a national blood establishment. Furthermore, approximately 3.1 million cHb measurements from the years 2000 to 2009 were included in analyses to correlate measured cHb value and Hb deferral rate. RESULTS: A significant correlation between the mean annual cHb and Hb deferral rate was observed in both women and men. The season of the donation was the strongest explanatory factor for the monthly variation of predonation cHb (explaining 25 and 31% of the variation in women and men, respectively). Batch-to-batch variation in HemoCue cuvettes explained 6.8% of monthly variation in women and 7.4% in men. Monthly changes in donors' age distribution explained 2.5% of monthly variation in women and 2.4% in men. CONCLUSION: Small and, in most clinical settings, negligible analytical variation in Hb measurement methods can have significant consequences when used for Hb screening of blood donors. This should be minimized by using methods in which analytical variation is under control and kept as low as possible.


Assuntos
Absorciometria de Fóton/métodos , Doadores de Sangue , Seleção do Doador , Hemoglobinometria/métodos , Hemoglobinas/análise , Testes Imediatos , Absorciometria de Fóton/instrumentação , Absorciometria de Fóton/normas , Fatores Etários , Seleção do Doador/normas , Seleção do Doador/estatística & dados numéricos , Feminino , Finlândia , Hemoglobinometria/instrumentação , Hemoglobinometria/normas , Humanos , Masculino , Testes Imediatos/normas , Controle de Qualidade , Valores de Referência , Reprodutibilidade dos Testes , Estações do Ano
13.
Rev Assoc Med Bras (1992) ; 64(4): 330-338, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30133612

RESUMO

OBJECTIVE: The current study was aimed to examine intra-individual variation on indicators of bone health in addition to whole-body plus appendicular tissue measurements using two concurrent assessments based on pencil beam and fan beam dual energy X-ray absorptiometry (DXA) systems in adult athletes from several sports. METHOD: Thirty-two male participants (27.6±10.1 years) were measured on anthropometry including multifrequency bioelectric impedance and air-displacement plethysmography. Bone mineral content (BMC), bone area, fat and lean soft tissue were derived using pencil beam (Lunar DPX-MD+) and fan beam (Lunar iDXA) absorptiometry. Bone mineral density (BMD) was obtained for the femoral neck, trochanter and triangle of ward. Finally, the right thigh was defined as a region of interest (ROI). Analyses comprised intra-class correlation (ICC), Effect size (d) from mean differences of repeated measurements, coefficient of variation (CV). RESULTS: ICC were >0.900 for all measurements. Intra-individual differences were large for BMC (d=1,312; CV=2,7%), bone area (d=1,761; CV=2,7%), fat tissue (d=1,612; CV=11%) and all indicators of appendicular lean soft tissue (d=1,237-1687; CV=2,0-4,1%). A very large difference (d=4,014; CV=8.4%) was diagnosed for lean soft tissue of the ROI. CONCLUSION: Although differences among concurrent instruments for BMC and bone area, the effect size of mean differences was negligible for BMD. Fat and lean soft tissue derived from DXA should be interpreted as reference values (not criterion) due to equipment-related variation, more apparently in the ROI values.


Assuntos
Absorciometria de Fóton/instrumentação , Atletas , Composição Corporal , Densidade Óssea , Osso e Ossos/diagnóstico por imagem , Adolescente , Adulto , Antropometria , Estudos Transversais , Impedância Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Pletismografia/métodos , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Adulto Jovem
14.
J Clin Endocrinol Metab ; 103(11): 4232-4240, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29982711

RESUMO

Purpose: This study aimed to examine the discrepancy in osteoporosis diagnoses between central quantitative computed tomography (cQCT) and dual-energy X-ray absorptiometry (DXA) and evaluated correlations among volumetric bone mineral density (vBMD), areal bone mineral density (aBMD), and trabecular bone score(TBS) in postmenopausal women who were undergoing TSH suppressive therapy. Methods: We enrolled a total of 81 postmenopausal patients [median age: 58 years; interquartile range (IQR): 57 to 60 years] receiving TSH suppressive therapy with levothyroxine after undergoing total thyroidectomy for papillary thyroid cancer. Patients were diagnosed by their bone mineral density (BMD) T-score and categorized according to a vBMD threshold of 120 mg/cm3 for osteopenia and a threshold of 80 mg/cm3 for osteoporosis. Results: When DXA and cQCT were compared, the BMD evaluation results differed in 76% of patients (n = 62; P < 0.001), and the detection rate of osteoporosis was 30.9% for cQCT and 21.0% for DXA. Sixty-two patients had discordant results; in 46 of these patients (74%) whose DXA T-scores were normal, the diagnosis shifted to osteopenia (n = 35) and osteoporosis (n = 11) according to the vBMD on cQCT (P < 0.001), and their vBMD values were significantly correlated with TBS (r = 0.293; P = 0.008). However, aBMD was not significantly correlated with TBS (r = 0.080; P = 0.480). TBS was significantly lower in patients with osteopenia (median: 1.35; IQR: 1.18 to 1.47) and osteoporosis (median: 1.28; IQR: 1.07 to 1.47) than in those with a normal BMD value (median: 1.37; IQR: 1.25 to 1.49; P = 0.041) on cQCT. There was no significant difference in TBS according to DXA BMD status (P = 0.200). Conclusions: DXA and cQCT yielded inconsistent results, and detection of osteopenia and osteoporosis was higher using cQCT. TBS showed a more significant correlation with vBMD than with aBMD.


Assuntos
Absorciometria de Fóton/métodos , Doenças Ósseas Metabólicas/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Tireotropina/antagonistas & inibidores , Tiroxina/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton/instrumentação , Densidade Óssea/efeitos dos fármacos , Doenças Ósseas Metabólicas/induzido quimicamente , Doenças Ósseas Metabólicas/epidemiologia , Estudos Transversais , Feminino , Humanos , Pessoa de Meia-Idade , Osteoporose/induzido quimicamente , Osteoporose/epidemiologia , Pós-Menopausa , Prevalência , Estudos Retrospectivos , Câncer Papilífero da Tireoide/cirurgia , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia , Tiroxina/administração & dosagem , Tomografia Computadorizada por Raios X/instrumentação
15.
Meat Sci ; 144: 91-99, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30008338

RESUMO

This experiment assessed the ability of an on-line dual energy x-ray absorptiometer (DEXA) installed at a commercial abattoir to determine carcase composition at abattoir chain-speed. 607 lamb carcases from 7 slaughter groups were DEXA scanned and then scanned using computed tomography to determine the proportions of fat (CT fat%), lean (CT lean%), and bone (CT bone%). Data between slaughter groups were standardised relative to a synthetic phantom consisting of Nylon-6. Models were then trained within each dataset using hot carcase weight and DEXA value to predict CT composition, and then validated in the remaining datasets. Results from across-dataset validation tests demonstrated excellent precision for predicting CT fat%, with RMSE and R2 values of 1.32 and 0.89, compared to values of 1.69 and 0.69 for CT lean%, and 0.81 and 0.68 for CT bone% which had less precision. Accuracy across datasets was also robust, with average bias values of 0.66, 0.83, and 0.51 for CT fat%, lean%, and bone%.


Assuntos
Matadouros , Absorciometria de Fóton/veterinária , Composição Corporal/fisiologia , Ovinos/fisiologia , Absorciometria de Fóton/instrumentação , Tecido Adiposo , Animais , Calibragem
16.
Endocrine ; 61(2): 336-342, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29948934

RESUMO

PURPOSE: Trabecular Bone Score (TBS) provides an indirect score of trabecular microarchitecture from lumbar spine (LS) dual energy X-ray absorptiometry. Increasing soft tissue thickness artifactually reduces TBS values; we evaluated the effect of a fictitious increase of soft tissue thickness on TBS and bone mineral density (BMD) reproducibility on a phantom model. METHODS: A Hologic spine phantom was scanned with a QDR-Discovery W Hologic densitometer. Fresh pork rind layers of 5 mm were used to simulate the in-vivo soft tissues. For each scan mode (fast array [FA], array, high definition [HD]), 25 scans were consecutively performed without phantom repositioning, at 0 (no layers), 1 cm, 3 cm, and 6 cm of thickness. BMD and TBS reproducibility was calculated as the complement to 100% of least significant change. RESULTS: Both BMD and TBS reproducibility slightly decreased with increasing soft tissue; this difference was statistically significant only for BMD using HD modality (reproducibility decreased from 99.4% at baseline to 98.4% at 6-cm of thickness). TBS reproducibility was slightly lower compared to that of BMD, and ranged between 98.8% (array, 0 cm) and 97.4% (FA, 6 cm). Without taking into account manufacturer BMI optimization, we found a progressive decrease of TBS mean values with increasing soft tissue thickness. The highest TBS difference between baseline scan and 6 cm was -0.179 (-14.27%) using HD. CONCLUSIONS: Despite being slightly lower than that of BMD, TBS reproducibility was not affected up to 6 cm of increasing soft tissue thickness, and was even less influenced by fat than BMD reproducibility.


Assuntos
Absorciometria de Fóton , Tecido Adiposo/anatomia & histologia , Osso Esponjoso/diagnóstico por imagem , Tecido Conjuntivo/anatomia & histologia , Músculos/anatomia & histologia , Imagens de Fantasmas , Absorciometria de Fóton/instrumentação , Absorciometria de Fóton/métodos , Absorciometria de Fóton/normas , Tecido Adiposo/patologia , Animais , Artefatos , Densidade Óssea , Osso Esponjoso/anatomia & histologia , Osso Esponjoso/patologia , Tecido Conjuntivo/diagnóstico por imagem , Tecido Conjuntivo/patologia , Músculos/patologia , Tamanho do Órgão/fisiologia , Imagens de Fantasmas/normas , Controle de Qualidade , Carne Vermelha , Reprodutibilidade dos Testes , Projetos de Pesquisa
17.
Rev. Assoc. Med. Bras. (1992) ; 64(4): 330-338, Apr. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-956459

RESUMO

SUMMARY OBJECTIVE: The current study was aimed to examine intra-individual variation on indicators of bone health in addition to whole-body plus appendicular tissue measurements using two concurrent assessments based on pencil beam and fan beam dual energy X-ray absorptiometry (DXA) systems in adult athletes from several sports. METHOD: Thirty-two male participants (27.6±10.1 years) were measured on anthropometry including multifrequency bioelectric impedance and air-displacement plethysmography. Bone mineral content (BMC), bone area, fat and lean soft tissue were derived using pencil beam (Lunar DPX-MD+) and fan beam (Lunar iDXA) absorptiometry. Bone mineral density (BMD) was obtained for the femoral neck, trochanter and triangle of ward. Finally, the right thigh was defined as a region of interest (ROI). Analyses comprised intra-class correlation (ICC), Effect size (d) from mean differences of repeated measurements, coefficient of variation (CV) RESULTS: ICC were >0.900 for all measurements. Intra-individual differences were large for BMC (d=1,312; CV=2,7%), bone area (d=1,761; CV=2,7%), fat tissue (d=1,612; CV=11%) and all indicators of appendicular lean soft tissue (d=1,237-1687; CV=2,0-4,1%). A very large difference (d=4,014; CV=8.4%) was diagnosed for lean soft tissue of the ROI. CONCLUSION: Although differences among concurrent instruments for BMC and bone area, the effect size of mean differences was negligible for BMD. Fat and lean soft tissue derived from DXA should be interpreted as reference values (not criterion) due to equipment-related variation, more apparently in the ROI values.


RESUMO OBJETIVO: O presente estudo examinou a concordância entre os indicadores de saúde óssea e composição tecidual resultantes da aplicação de equipamentos concorrentes de absorciometria de raios X de dupla energia (DXA). MÉTODO: A amostra (n = 32), com 27,6 ± 10,1 anos de idade avaliados antropometricamente, inclui impedância bioelétrica com multifrequência e pletismografia de ar deslocado. O conteúdo mineral ósseo (CMO), a área de tecido ósseo, o tecido magro e o tecido gordo de corpo inteiro foram obtidos considerando o modo pencil beam (Lunar DPX-MD+) e o fan beam (Lunar iDXA). Para cada um dos equipamentos, foi efetuado um scanner proximal do fêmur, sendo produzida informação sobre a densidade mineral óssea (DMO) do colo, nomeadamente triângulo de Ward, trocanter e haste. Na fase de processamento, foi definida uma região de interesse (ROI; coxa direita). As análises compreenderam a diferença de médias de medidas repetidas com cálculo da magnitude de efeitos (d), coeficiente de correlação intraclasse (CCI), coeficiente de variação (CV). RESULTADOS: Foram obtidos CCI>0,900 para todas as medidas, com diferenças intraindividuais largas apenas para CMO (d = 1,312; CV = 2,7%), área de tecido ósseo (d = 1,761; CV = 2,7%), tecido gordo total (d = 1,612; CV = 11%) e tecido magro em todos os segmentos (d = 1,237-1,687; CV = 2,0-41%). A massa magra da ROI apresentou uma variaçāo intraindividual muito larga (d = 4,014; CV = 8,4%). CONCLUSÃO: Foram encontradas diferenças negligenciáveis para a DMO de corpo todo. As medidas de massa gorda e massa magra obtidas por DXA nāo devem ser tidas como critério, mas antes como referenda, muito especialmente quando se delimita uma ROI.


Assuntos
Humanos , Masculino , Adolescente , Adulto , Adulto Jovem , Composição Corporal , Osso e Ossos/diagnóstico por imagem , Absorciometria de Fóton/instrumentação , Densidade Óssea , Atletas , Pessoa de Meia-Idade , Pletismografia/métodos , Valores de Referência , Antropometria , Estudos Transversais , Reprodutibilidade dos Testes , Impedância Elétrica , Estatísticas não Paramétricas
18.
Spinal Cord ; 56(10): 987-995, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29511310

RESUMO

STUDY DESIGN: Repeated measures design. OBJECTIVES: To determine the reproducibility of total-body and regional-body composition assessments from a total-body scan using dual-energy x-ray absorptiometry (DXA) in persons with spinal cord injury (SCI). METHODS: Twenty-four individuals with SCI completed within-day short-term precision testing by repositioning study participants between scans. An additional and separate cohort of 22 individuals with SCI were scanned twice on a GE-Lunar DXA scanner separated by a 4-week interval to assess the long-term precision assessment. The root mean square coefficient of variation percent (RMS-CV%) values for the regional and total body composition was calculated. RESULTS: For the same day, short-term precision assessment, the RMS-CV% for each region did not exceed 5.6, 2.7, 3.8, 6.5, 5.8, and 2.3% for arms, legs, trunk, android and gynoid regions, and total body mass, respectively. In the long-term precision assessment, the RMS-CV% for each region did not exceed 6.0, 3.0, 4.4, 8.2, 3.4, and 2.0% for arms, legs, trunk, android, gynoid, and total body mass. Moreover, the interclass-correlation coefficient in the long-term precision group demonstrated excellent linear agreement between repeat scans for all regions (r > 0.97). CONCLUSIONS: The precision error of the total body composition variables in our SCI cohort was similar to those reported in the literature for nondisabled individuals, and the precision errors of the regional body composition compartments were notably higher, but similar to the regional precision errors reported in the general population.


Assuntos
Absorciometria de Fóton , Composição Corporal , Traumatismos da Medula Espinal/diagnóstico por imagem , Imagem Corporal Total , Absorciometria de Fóton/instrumentação , Adolescente , Adulto , Doença Crônica , Humanos , Interpretação de Imagem Assistida por Computador , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Imagem Corporal Total/instrumentação , Imagem Corporal Total/métodos , Adulto Jovem
19.
J Xray Sci Technol ; 26(3): 395-412, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29562584

RESUMO

BACKGROUND: In general, the image quality of high and low energy images of dual energy X-ray absorptiometry (DXA) suffers from noise due to the use of a small amount of X-rays. Denoising of DXA images could be a key process to improve a bone mineral density map, which is derived from a pair of high and low energy images. This could further improve the accuracy of diagnosis of bone fractures and osteoporosis. OBJECTIVE: This study aims to develop and test a new technology to improve the quality, remove the noise, and preserve the edges and fine details of real DXA images. METHODS: In this study, a denoising technique for high and low energy DXA images using a non-local mean filter (NLM) was presented. The source and detector noises of a DXA system were modeled for both high and low DXA images. Then, the optimized parameters of the NLM filter were derived utilizing the experimental data from CIRS-BFP phantoms. After that, the optimized NLM was tested and verified using the DXA images of the phantoms and real human spine and femur. RESULTS: Quantitative evaluation of the results showed average 24.22% and 34.43% improvement of the signal-to-noise ratio for real high and low spine images, respectively, while the improvements were about 15.26% and 13.55% for the high and low images of the femur. The qualitative visual observations of both phantom and real structures also showed significantly improved quality and reduced noise while preserving the edges in both high and low energy images. Our results demonstrate that the proposed NLM outperforms the conventional method using an anisotropic diffusion filter (ADF) and median techniques for all phantom and real human DXA images. CONCLUSIONS: Our work suggests that denoising via NLM could be a key preprocessing method for clinical DXA imaging.


Assuntos
Absorciometria de Fóton/métodos , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Absorciometria de Fóton/instrumentação , Fêmur/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Imagens de Fantasmas , Razão Sinal-Ruído , Coluna Vertebral/diagnóstico por imagem
20.
Med Phys ; 45(1): 81-91, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29080282

RESUMO

PURPOSE: Dual-energy X-ray absorptiometry (DXA) is the gold standard technique to measure areal bone mineral density (aBMD) for the diagnosis of osteoporosis. Because DXA relies on the attenuation of photon to estimate aBMD, deposition of bone-seeking metallic elements such as strontium, lead, and aluminum that differ in atomic numbers from calcium can cause inaccurate estimation of aBMD. Quantitative ultrasound (QUS) is another technique available to assess bone health by measuring broadband ultrasound attenuation (BUA), speed of sound (SOS), and an empirically derived quantity called stiffness index (SI). Because the acoustic properties are not prone to significant change due to changes in microscopic atomic composition of bone, it is hypothesized that QUS is unaffected by the presence of bone-seeking elements in the bone. The objective of this study was to investigate the effect of strontium, lead, and aluminum on DXA-derived aBMD and QUS parameters using bone-mimicking phantoms compatible with both techniques. METHODS: Bone-mimicking phantoms were produced by homogeneously mixing finely powdered hydroxyapatite compounds that contain varying concentrations of strontium, lead, or aluminum with porcine gelatin solution. Seven strontium-substituted phantoms were produced with varying molar ratio of Sr/(Sr + Ca) ranging from 0% to 2%. Four lead-doped phantoms and four aluminum-doped phantoms were constructed with the respective analyte concentrations ranging from 50 to 200 ppm. An additional 0 ppm phantom was produced to be used as a baseline for the lead and aluminum phantom measurements. All phantoms had uniform volumetric bone mineral density (vBMD) of 200 mg/cm3 , and were assessed using a Hologic Horizon® DXA device and a Hologic Sahara® QUS device. Furthermore, theoretical aBMD bias for mol/mol% substitution of calcium with the three bone-seeking elements was calculated. RESULTS: Strong positive linear relationship was found between aBMD measured by DXA and strontium concentration (P < 0.001, r = 0.995). From the measurement of lead and aluminum phantoms using DXA, no statistically significant relationship was observed between aBMD and the analyte concentrations. For the QUS system, with an exception of BUA and lead concentration that exhibited statistically significant relationship (P < 0.038, r = 0.899), no statistically significant change was observed in all QUS parameters with respect to the clinically relevant concentration of all three elements. The calculated theoretical aBMD bias induced by 1 mol/mol% substitution of calcium with strontium, lead, and aluminum were 10.8%, 4.6%, and -0.7%, respectively. CONCLUSION: aBMD measured by DXA was prone to overestimation in the presence of strontium, but acoustic parameters measured by QUS are independent of strontium concentration. The deviation in aBMD induced by the clinically relevant concentrations of lead and aluminum under 200 ppm could not be detected using the Hologic Horizon® DXA device. Furthermore, the SI measured by the QUS system was not affected by lead or aluminum concentrations used in this study.


Assuntos
Absorciometria de Fóton/instrumentação , Alumínio , Osso e Ossos/diagnóstico por imagem , Chumbo , Imagens de Fantasmas , Estrôncio , Ultrassonografia/instrumentação , Densidade Óssea , Osso e Ossos/fisiologia
SELEÇÃO DE REFERÊNCIAS